AL Series
EMMA with vertical type full automation. With newly developed auto loader/unloader on the side 24 hours unattended testing is now possible. Once the boards are stacked on the loader, suction pads automatically conveys the boards to the test area. Once the test is complete, boards are speedily transferred to unloader, separate to PASS and FAIL boards.
Boards Transfer Method: Conveyer Method
Max. Stackable Boards
Autoloader: 200pcs (when board thickness is 1.6mm. Max. stackable weight: 80kg)
Unloader: PASS Boards 200 pcs, FAIL Boards 60 pcs (when board thickness is 1.6mm. Max. stackable weight: 80kg)
Inclusion of stamp unit is available (Optional).
Supports multi-image boards
* Multiple boards with different size may be stacked at same time.
* Stackert may be separated to devide into PASS and FAIL boards.
* Conventional E8M cannot be connected to full automation
Max. Test Area | 24 x 20" (610x510mm) |
---|---|
Max. Transferable Panel Size | 24.4 x 20.4" (620x520mm) |
Number of Probes | 4 Front, 4 Rear |
Min. Board Size *1 | 3.9 x 3.9" (100x100mm) |
Min. Transferable Panel Size | 8.9 x 8.9" (225 x 225mm) |
Board Thickness for Clamping *2 | 0.02-0.2" (0.5-5.0mm) |
Max. Transferable Weight *3 | 6.6lbs. (3kg) |
Clamp Margin | 0.12-0.39" (3.0-10mm) |
Untestable Area *4 | 0.039" (1mm) from Clamp Margin |
Repeatable Accuracy | ±0.16mil (±4µm) |
Resolution | 0.08mil (2µm) |
Min. Pad Pitch *5 | 4.0mil (100µm) |
Min. Pad Size *6 | 2.0mil (50µm) |
Test Voltage of Resistance Measurement | Continuity test: 0-10V Isolation test: 250V(500V/1000V option) |
Test Current of Resistance Measurement | Continuity test: 2.5µA-150mA |
Clamp System | Pneumatic |
CCD Camera | 4 Front, 4 Rear |
Printer | external |
Air Requirements | Pressure: 0.5MPa, Consumption: 5.3ft³/min.(150ℓ/min.) |
Power Supply *7 | 20A (Single Phase AC200-240V 50/60Hz) |
Weight (Main Unit, Loader/Unloader) | 7407lbs. (3360kg) |
Dimensions [ Unit: inch(mm) ] | ![]() |
*1 | Min. size that can be clamped by the tester section. |
*2 | Boards warpage including board thickness shall be within 5mm. Min. board thickness requires the board to be free of warpage and able to stand indipendintly when held perpendicularly. |
*3 | When all 10 suction pads at loader pick up section are used. |
*4 | With needle probes. Value shall change when other probes are used. |
*5 | With TIPRB-PB-N110, TIPRB-PB-N111 probe. |
*6 | With TIPRB-PB-B210, TIPRB-PB-B211 probe. |
*7 | Power Supply: There may be cases with inrush current equaling to 10 times of the rated and flowing when the power is turned ON. Please choose the breaker that will not cause any malfunction by such inrush current. |
System Requirements | 1) Control PC & Monitor 2) PC & Monitor for Test Data Editing. † 1) and 2) can be completed in one PC. * Please inquire our sales for PC specification. |
---|---|
Probe Type | Users can choose one of different types of probes depending on tester models. Please ask our sales for specifications of each probe & PC. |
Software | EMMA2010 for Control PC is included, but all other software is optional (supporting OS are Windows 7 / Windows 8 / Windows 10). |
Operating Conditions | · 70-75°F (21-24°C), 30-70% relative humidity †Do not use under the environment that has heavy condensing, dust, vibration, and/or corrosive gas. · Atmospheric Dew Point: -14°C or below (at 0.7Mpa, dew point is 15°C or below) · Oil Mist Concentration: 1mg/㎥ (ANR) or below |